Wavetek 147 Spécifications Page 275

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 410
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 274
Description and Basic Operation of the SDA-5500 and 5510: Using Auto Test
251
13
Fig. 13-26 Test Location Parameters
There are five types of locations associated with a cable system: Trunk Amp,
Headend, Line Extender, Fiber Node, and Field Test. Some of the
parameters do not apply to certain types of locations. The following table
Table 13-1 Test Location Parameters and Values
Parameter Minimum Maximum Default Units
Area 15 character alpha-numeric field
Amp ID 15 character alpha-numeric field
Power Configuration IN / OUT/ THROUGH
Feeder Maker Config 1 9 1
Trunk Termination NO YES NO
Voltage Setting LOW / MID / HIGH
Reverse Pad -100.0 +100.0 0.0 dB
Reverse Equalizer -100.0 +100.0 0.0 dB
Forward Pad -100.0 +100.0 0.0 dB
Forward Equalizer -100.0 +100.0 0.0 dB
Vue de la page 274
1 2 ... 270 271 272 273 274 275 276 277 278 279 280 ... 409 410

Commentaires sur ces manuels

Pas de commentaire