4-15
Label
The label is provided to associate a channel's number with it's
programming. Using the alpha keys, label the channel with a desired
name (up to four characters). "Special" characters can be selected
using the up/down arrow keys. The label will appear to the left of the
channel number on most screens.
Sweep Channel
Y/N - Designates that the channel will be used for Sweep
measurements.
NOTE: Adding sweep points at increments other than 250 kHz will
slow the sweep speed by 15 msecs per non-250 kHz
increment.
Measurement Bandwidth Adjustments
To edit the bandwidth, cursor to the Measurement BW selection.
The bandwidth can be adjusted by using the UP and DOWN arrow
keys or by entering a value using the numeric keypad and then
pressing the ENTER key. The FCC specification for C/N measure-
ments is a bandwidth of 4.200 MHz. CATV organizations outside of
the United States may have different requirements.
Noise Offset Frequency Adjustments
The frequency at which the noise level is measured is the Carrier
frequency plus the noise offset. To adjust the noise offset, cursor to
the Noise Offset selection. The offset can be adjusted by using the
UP and DOWN arrow keys or by entering a value using the numeric
keypad and then pressing the ENTER key.
Tilt Channel
Y/N - Designates which channels are used for the Tilt mode. Up to
nine channels can be designated as Tilt channels.