4-29
Scan Rate
Two scan rates are available in the Scan mode, normal and fast. The
scan rate is selected in the Measurement Setup menu. The Fast scan
feature allows for rapid scan displays, while sacrificing accuracy.
Normal scan rate is slower, but much more accurate. An indicator
appears in the upper left hand corner of the Scan screen when the
Fast Scan mode is selected.
Audio Carriers
If desired, the audio carriers can be omitted resulting in a faster scan.
This feature is selected in the Measurement Setup menu. An
indicator appears in the upper left hand corner of the Scan screen
when audio carriers are omitted.
Limits
The Limits feature allows for comparison of the current scan mea-
surement with the "FCC" limits that are defined in Setup. There are
two parts to this feature.
When an out of tolerance condition exists a set of annunciators will
appear below the scan graph. The annunciators indicate the following
out of tolerance conditions:
• Adjacent Channel Error
• Video Level Too High/Low
VA Too High/Low
The limit annunciators are updated with each scan update.