4-18
Warning: Subscriber interference could result, if the frequency is set
to a local carrier frequency.
• Sweep Telemetry On/Off - When turned on, will modulate
the CW signal similar to the telemetry signal.
4.3.2 Measurements Setup
Temperature Unit
Use the UP and DOWN arrow keys to select the desired temperature
units (°C, °F).
Signal Level Units
Use the UP and DOWN arrow keys to select the desired level units
(dBmV, dBµV, dBm).
Test Point Compensation
Test Point Compensation is used to account for loses associated with
certain amplifiers. Use the UP and DOWN arrow keys or the numeric
entry keys to enter the Test Point Compensation. (-100.0 to +100.0
dB in 0.1 dB steps).